Compare our products

Eyestar 900 Lenstar 900
Applications
Cataract surgery ● ●
Refractive surgery ● ●
Anterior chamber analysis ● −
IOL calculation ● ●
Premium IOL calculation ● ○
Myopia management ○ ○
Biometry data
Biometry (AL, ACD, LT, CCT) ● ●
Keratometry (Dual zone anterior) ● ●
Anterior corneal topography ● ○
Posterior corneal topography ● −
Pupillometry ● ●
White-to-white ● ●
Measurements
Technology Swept-Source-OCT OCLR
A-Scan biometry ● ●
B-Scan biometry ● −
Measurement pattern Mandala-Scan, Virtual B-Scan, A-Scan A-Scan
Access to A-scan ● ●
Access to B-scan ● −
Manual exclusion of outliers ●
Adjustment of A-scan measurement gates ●
Central corneal Thickness (CCT) ●
Anterior Chamber Depth (ACD) ● ●
Anatomic Anterior Chamber Depth (AD) ● ●
Lens Thickness (LT) ●
Vitrous Chamber Depth (VCD) − −
Standard deviation of repeated measurements ●
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power ● ●
Astigmatism power and orientation ● ●
Flat meridian radius ● ●
Steep meridian radius ● ●
Flat meridian orientation ● ●
Steep meridian orientation ● ●
Topography measurements
Technology Swept-Source-OCT Optional Placido, 11-Ring
Anterior simulated keratometry ● ○
Posterior simulated keratometry ● −
Anterior simulated astigmatism (power and orientation) ●
Posterior simulated astigmatism (power and orientation) ●
Axial curvature map ● ○
Tangential curvature map ● ○
Spherical elevation map ● ○
Torical elevation map ●
Pachymetry map ● −
Zernike analysis / wavefront analysis ●
Vision simulation ●
Corneal maps diameter (mm / inch) up to 6mm / up to 0.24 inches
OCT imaging
Technology Swept Source OCT
Radial scans ●
Display of the maximal crystalline lens tilt ●
Display of the maximal IOL tilt ●
Measurement of the lens/IOL tilt ●
Pupillometry measurements
Technology Infra-Red Photography Infra-Red Photography
Pupil Diameter (PD) ● ●
Pupil center (barycenter) ● ●
Infra-red image ●
White-to-white
Technology Hi-Res Color Photography Hi-Res Color Photography
Iris diameter (ID) ● ●
Iris center (barycenter) ● ●
Color photography ●
Measurement process
Eye positioning Fully automatic Semi automatic or manual
Eye tracking Automatic Automatic or manual
Dense cataract mode ● ●
Measurement mode selection ● ●
"Normal" eye ● ●
Aphakic eye ● ●
Pseudophakic eye ● ●
Silicone-filled eye ● ●
Mode combination ● ●
IOL calculation
Hill-RBF Method ●
Hill-RBF / Abulafia Koch Toric ●
Barrett Universal II ● ●
Barrett True-K Toric ● ●
Barrett Toric ●
Haigis ● ●
Hoffer Q ● ●
Holladay 1 ● ●
Olsen ●
SRK II and SRK/T ● ●
Masket / Modified Masket ● ●
Shammas No-History ● ●
IOL workflow
Personalization of IOL constants ● ●
IOL calculation on viewing stations ●
Myopia management
AMMC by Kaymak ○ ○
Axial Length Growth Speed ○ ○
Axial Length Normative Data ○ ○
Refractive Myopia Progression Prediction ○ ○
Myopia Report for Parent Education ○ ○
Software modules
EyeSuite Basic ● ●
EyeSuite Biometry (Cataract Suite) ● ●
EyeSuite Anterior Chamber Suite ● −
EyeSuite IOL Toric Planner ● ○
EyeSuite Myopia ○ ○
EyeSuite Myopia AMMC ○ ○
Accessories
Instrument tables ○ ○
Headrest ● ○
Chinrest ● ○
External PC (Windows only) ○ ●
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface) ● ●
DICOM (SCU) ○ ○
EyeSuite Viewing Stations ● ●
Connect to network printer ● ●
Connect to shared folder ● ●
Connect to remote database ● ●
Data import
EyeSuite Script Language Refraction Data ●
Dimensions
Width (cm / inch) 48 cm / 18.9 inches 31 cm / 12.2 inches
Depth (cm / inch) 56 cm / 22 inches 26 cm / 10.23 inches
Height (cm / inch ) 46 cm / 18.11 inches 42 cm / 16.53 inches
Weight (kg / pounds) 31 kg / 68.34 lbs
Electrical requirements
Line voltage 100 - 240V 100-240V
Line frequency 50 - 60Hz 50-60Hz
Power consumption 200VA
Safety certifications
Laser Class 1 ● ●
● standard | ○ optional | − not available | □ not recommended

Eyestar 900

Swept-source OCT

A fully-automated ophthalmic device for both cataract and refractive surgery, Eyestar 900 provides cornea-to-retina biometry. It allows topographic assessment of the anterior and posterior corneal surface and visualisation of the anterior chamber, including the lens. Cutting-edge swept-source OCT technology enables precise measurement of the entire eye and offers comprehensive data and high-quality images of the anterior chamber.

Lenstar 900

Reliable cataract diagnosis

Lenstar 900 supports ophthalmic surgeons in the cataract planning process to provide excellent refractive outcomes. A comprehensive software suite delivers fast and precise measurements, intuitive data representation, and latest-generation planning and analysis tools. Quick measurement acquisition, automation support, and ergonomic user interfaces ensure that the process of diagnostic data acquisition is pleasant for surgeon and patient alike. 

How can we help?